Rent Fluke Networks DSP-FTA430 LAN Cable Certifiers

Fluke FTA-430 Fiber Module, Fluke Networks keeps its eye on the future – so you don’t have to. Powerful, High Definition Diagnostics

Complete solution for testing and certifying high-speed Fiber Networks

Fluke Networks offers the most complete line of Fiber Test Adapters for testing and certifying Single mode, Gigabit and Single-Mode fiber optic cabling systems. These Fiber Test Adapters are high-performance, high-productivity fiber test options for the DSP-4000, DSP-4100 and DSP-4300 Digital CableAnalyzers.

DSP-FTA430 Singlemode Fiber Test Adapter

Uses light sources at 1310 nm and 1550 nm wavelenghts

Rent Microtest DSP-FTA430 LAN Cable Certifiers

Test one fiber and two wavelengths simultaneously, automatically saving the test results.
Perform bi-directional testing on both fibers under test and save results for both in one record.
Utilize Fluke Networks’ CableManager Software for comprehensive results management and report generation.
Automatically measure length and propagation delay along with loss.
Verify optical connectivity and determine which fibers go to which connectors at a patch panel.
Communicate with a person on the other end of the fiber.
Track the maximum and minimum power throughput of the test.
Withstand drops and other mishaps that occur on the job.

DSP-FTA430 Specifications

General Specifications

Power supply: ±6 V supplied by the DSP-4000 test tool.
Temperature range: Operating: 0 ºC to +40 ºC; Storage: -10 ºC to +60 ºC
Warm-up time: 5 minutes
Humidity range: Operating: 0 % to 75 % RH, non-condensing
Storage: 0 % to 95 % RH, non-condensing
Dimensions: 3.3” x 4.6” x 1.9” (8.3 cm x 11.6 cm x 4.7 cm)
Weight: 7.6 oz (215 g)

Rent Fluke Networks DSP-FTA430

Optical Transmitter

Connector: SC, multimode
Emitter type:
FTA420 – Multimode LED
FTA430 – Singlemode laser
FTA440 – 850 nm Vertical Cavity Surface Emitting Laser (VCSEL);
1310 nm FP laser
Wavelengths:
FTA420 – 850 nm and 1300 nm
FTA430 – 1310 nm and 1550 nm
FTA 440 – 850nm and 1310 nm
Power output:
FTA420 -20 dBm (10 mW), typical (into 62.5/125 mm fiber)
FTA430 and FTA440 -10 dBm
Power output stability (8 hours): ±0.25 dB at 23 °C

Optical Receiver

Power measurement accuracy: ±0.25 dBm at 23 °C, 45 % RH to 75 % RH, -20
dBm for 850 nm and 1300 nm, -10 dBm for 1550 and 1625 nm
Connector: SC, multimode or singlemode
Detector type: InGaAs
Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, 1550 and 1625 nm.
Power measurement range: +3 dBm to -50 dBm
Power measurement linearity: ±0.25 dB at 23 °C
Length Measurement:
Measured in Loopback Mode with included SC/ST patch cables and
one pair of ST/ST adapters.
FTA420 – 5000 meters of 62.5 um multimode cable
FTA430 – 10000 meters of singlemode cable
FTA440 – 5000 meters of 50.0 um multimode cable
Length measurement accuracy: ±1.5 m plus 2 % of length

Lease Fluke Networks DSP-FTA430 LAN Cable Certifiers Rental